Flagship high-voltage power transformer for sub-transmission, industrial main supply, and generator step-up. OLTC, full type-tested, built to IEC 60076 / IEEE C57.

6.3–200 MVACapacity
110 kVVoltage
IEC 60076Standard
110kV Power Transformer

Technical Parameters

Standard parameter ranges for this model. Special requirements can be assessed by our engineering team — contact us for custom specifications.

ParameterStandard Range
Rated capacity6.3–200 MVA (typical: 20/31.5/40/50/63/75/100/120/150/200)
Primary voltage110 kV (max 126 kV)
Secondary voltage10, 11, 20, 35 kV / custom
Frequency50 Hz or 60 Hz
Phase3-phase
Vector groupYNd11, YNd1, YNa0 (custom)
Impedance10.5% – 14% (per spec)
Cooling methodONAN / ONAF / ODAF
Tap changerOn-load (OLTC) ±8×1.25%
Insulation levelLI550AC230 (110kV) / per voltage class
Temperature rise65K (oil); 65K (winding)
No-load lossPer IEC 60076 / customer spec
Load lossPer IEC 60076 / customer spec
Noise level≤70 dB (per IEC 60076-10)
Protection levelIP00 indoor; IP54 outdoor available
Applicable standardsIEC 60076, IEEE C57.12.00, GB/T 6451
Ambient temperature-25°C to +40°C
Altitude≤1000m (derating above)
AccessoriesOLTC, Buchholz, pressure relay, DGA, temp gauges, surge arrester, control cubicle
Special parameters (non-standard voltage, capacity, impedance, or environmental conditions) can be assessed by our engineers. Response within 12 hours, full proposal within 48 hours.

Product Advantages

Verifiable benefits — not empty claims. Here’s exactly what you get when you choose JINXING.

🧪

Full Type Test

Impulse, PD, temp-rise, sound — witnessed per IEC 60076.

⏱️

48h Quote / 3–5 Day Custom

Standard quoted in 48h; custom in 3–5 working days.

🌡️

OLTC + Monitoring

On-load tap changer with online DGA and temperature monitoring.

📄

English Documentation

Spec, GA drawing, test report, manual — all English.

🏷️

Material Options

Core steel, copper, oil brand — selectable per request.

👁️

Third-Party Witness

SGS/CiT/Intertek witness FAT welcome.

🏭

OEM Support

Private label and custom branding available.

📦

Export Packing

Sea-worthy, shock-fixed for large-unit shipping.

Power transformer bushings, cooling system and component detailsComponents and connection details

Applications

Where this transformer is used — connecting the product to real-world industry applications.

Sub-transmission

110kV regional transmission substations.

🔋

Generator Step-up

Power plant GSU — 110kV grid connection.

🏭

Industrial Main Supply

Large industrial plants — 110kV main power supply.

🏙️

City Substation

Urban distribution substations — 110/10kV.

☀️

Solar/Wind Farm

Main step-up for renewable energy plants.

🛢️

Oil & Gas

Refinery and processing facility main supply.

Quality Proof — 9-Step Manufacturing Process

Every transformer passes through 9 quality-controlled stages, from raw material to shipping. Full traceability with documentation at every step.

110kV transformer manufacturing and quality testing process
1

Material Inspection

Raw material verification — core steel, copper, oil, accessories checked against certificates before production.

2

Core Cutting

CNC step-lap core cutting for low-loss grain-oriented silicon steel. Core loss measured before assembly.

3

Winding

Controlled winding tension, turn-count verification, and insulation paper application for each coil.

4

Assembly

Core-coil assembly with dimensional checks for fit, clearance, and clamping force.

5

Vacuum Drying

High-vacuum drying ovens remove moisture from insulation before oil impregnation.

6

Oil Filling

Filtered insulating oil with breakdown voltage >70kV/2.5mm and moisture <10ppm.

7

Final Testing

Full routine test per IEC 60076-1 — insulation, resistance, ratio, losses, withstand.

8

Packing

Sea-worthy export packing with shock-fixed crating for ocean shipping.

9

Shipping

On-time delivery with documentation — test reports, drawings, manuals in English.

Need a Custom Transformer Solution?

Our engineering team can assess non-standard voltage, capacity, impedance, or environmental conditions — and deliver a full proposal within 48 hours.