Power Transformer

Inverter Duty Transformer

Specifically designed for inverter-fed loads. K-factor rated, eddy-current loss controlled for harmonic-rich loads from VFDs, UPS, and power electronics.

CustomCapacity
0.4, 0.69, 0.8, 10, 20, 35 kVVoltage
IEC 60076Standard
Inverter Duty Transformer — product viewProduct view

Technical Parameters

Standard parameter ranges for this model. Special requirements can be assessed by our engineering team — contact us for custom specifications.

ParameterStandard Range
Rated capacityCustom (typical: 100–3150 kVA)
Primary voltage0.4, 0.69, 0.8, 10, 20, 35 kV
Secondary voltage0.4 kV / custom
Frequency50 Hz or 60 Hz (plus harmonic spectrum)
Phase3-phase
Vector groupDyn11, Dyn5, Yyn0
Impedance4.0% – 8.0% (K-factor adjusted)
Cooling methodAN/AF (dry-type) or ONAN/ONAF (oil)
Tap changerOff-circuit (OCTC) ±2×2.5%
Insulation levelPer voltage class
Temperature rise100K (F, dry) / 65K (oil); harmonic-adjusted
No-load lossPer IEC 60076
Load lossPer IEC 60076 (K-factor adjusted, stray loss controlled)
Noise level≤55 dB
Protection levelIP23 indoor / IP54 outdoor
Applicable standardsIEC 60076, IEEE C57.12.00, UL 1561
Ambient temperature-25°C to +50°C
Altitude≤1000m
AccessoriesTemp sensors, K-factor rating plate, enclosure
Special parameters (non-standard voltage, capacity, impedance, or environmental conditions) can be assessed by our engineers. Response within 12 hours, full proposal within 48 hours.

Product Advantages

Verifiable benefits — not empty claims. Here’s exactly what you get when you choose JINXING.

〰️

K-Factor Rated

K-4 to K-20 rating — handles harmonic loads from VFDs, UPS, inverters.

Low Stray Loss

Eddy-current loss controlled — prevents overheating from harmonics.

🔧

Custom Harmonic Design

Designed for your specific harmonic spectrum and THD.

🧪

Full Routine Test

IEC 60076-1 + harmonic loss verification.

📄

English Docs

Complete documentation including K-factor calculation.

🏭

OEM Support

Private label for drive and UPS manufacturers.

Inverter Duty Transformer — construction details and componentsDetails and components

Applications

Where this transformer is used — connecting the product to real-world industry applications.

⚙️

VFD Applications

Variable frequency drive power supply transformers.

🔋

UPS Systems

UPS input/output isolation transformers.

☀️

Solar Inverters

PV inverter step-up — harmonic-tolerant.

🏭

Industrial Drives

Process industry drive-fed load transformers.

💻

Data Centers

UPS and server power supply — harmonic adaptation.

Quality Proof — 9-Step Manufacturing Process

Every transformer passes through 9 quality-controlled stages, from raw material to shipping. Full traceability with documentation at every step.

Inverter Duty Transformer — manufacturing and quality testingManufacturing and testing
1

Material Inspection

Raw material verification — core steel, copper, oil, accessories checked against certificates before production.

2

Core Cutting

CNC step-lap core cutting for low-loss grain-oriented silicon steel. Core loss measured before assembly.

3

Winding

Controlled winding tension, turn-count verification, and insulation paper application for each coil.

4

Assembly

Core-coil assembly with dimensional checks for fit, clearance, and clamping force.

5

Vacuum Drying

High-vacuum drying ovens remove moisture from insulation before oil impregnation.

6

Oil Filling

Filtered insulating oil with breakdown voltage >70kV/2.5mm and moisture <10ppm.

7

Final Testing

Full routine test per IEC 60076-1 — insulation, resistance, ratio, losses, withstand.

8

Packing

Sea-worthy export packing with shock-fixed crating for ocean shipping.

9

Shipping

On-time delivery with documentation — test reports, drawings, manuals in English.