High Voltage Power

220kV Power Transformer

Extra-high-voltage power transformer for main transmission networks and large generation step-up. Built to IEC 60076 / IEEE C57 standards, with OLTC and full type test support.

31.5–400 MVACapacity
220 kVVoltage
IEC 60076Standard
220kV Power Transformer

Technical Parameters

Standard parameter ranges for this model. Special requirements can be assessed by our engineering team — contact us for custom specifications.

ParameterStandard Range
Rated capacity31.5–400 MVA (typical: 120/150/180/240/300/370 MVA)
Primary voltage220 kV (max 252 kV)
Secondary voltage35 / 66 / 110 kV / custom
Frequency50 Hz or 60 Hz
Phase3-phase (single-phase bank on request)
Vector groupYNd11, YNa0, YNd1 (custom available)
Impedance12% – 16% (per spec & system fault level)
Cooling methodONAN / ONAF / ODAF / OFAF
Tap changerOn-load (OLTC) ±8×1.25% — neutral or line-end
Insulation levelLI950AC395 (220kV) / per voltage class
Temperature rise65K (oil); 65K (winding, F class)
No-load lossPer IEC 60076 / customer spec
Load lossPer IEC 60076 / customer spec
Noise levelPer IEC 60076-10 (typically ≤75 dB)
Protection levelIP00 (indoor substation); IP54 outdoor enclosure available
Applicable standardsIEC 60076, IEEE C57.12.00, GB/T 6451
Ambient temperature-25°C to +40°C (higher temp with derating)
Altitude≤1000m (derating above, per project)
AccessoriesOLTC, Buchholz, pressure relay, online DGA, oil/winding temp, surge arrester, control & protection cubicle
Special parameters (non-standard voltage, capacity, impedance, or environmental conditions) can be assessed by our engineers. Response within 12 hours, full proposal within 48 hours.

Product Advantages

Verifiable benefits — not empty claims. Here’s exactly what you get when you choose JINXING.

🧪

Full Type Test Support

Impulse, PD, temp-rise, sound level — witnessed per capability. Type test reports on file.

⏱️

3–5 Day Custom Proposal

Large units quoted per project. Engineering assessment within 3–5 working days.

🌡️

Heavy-Duty Design

Winding & clamping designed for high system fault level. Short-circuit strength per IEC 60076-5.

📄

Complete English Docs

Specification, GA drawing, test report, nameplate, operation manual — all in English.

👁️

Third-Party Witness

FAT with SGS/CiT/Intertek welcome. Online DGA and temp monitoring included.

🏭

OEM Support

OEM branding available. Built to customer drawings and specifications.

🔧

OLTC + Monitoring

On-load tap changer with online DGA, oil/winding temperature, and OLTC monitoring.

📦

Heavy Export Packing

Sea-worthy, shock-fixed for large-unit ocean shipping.

220kV transformer components, bushings and cooling system details

Applications

Where this transformer is used — connecting the product to real-world industry applications.

Transmission Network

Main transmission substations — 220kV step-down to 110/66/35kV.

🔋

Generation Step-up

Large generator step-up (GSU) — 220kV connection to grid.

🏭

Heavy Industry

Steel, cement, chemical plants — main power supply at 220kV.

🏙️

Regional Hub Substation

Regional grid interconnection and hub substations.

🔌

Grid Interconnection

Interconnection between regional grids at 220kV level.

🛢️

Oil & Gas

Large processing facilities requiring 220kV main supply.

Quality Proof — 9-Step Manufacturing Process

Every transformer passes through 9 quality-controlled stages, from raw material to shipping. Full traceability with documentation at every step.

220kV transformer manufacturing and quality testing process
1

Material Inspection

Raw material verification — core steel, copper, oil, accessories checked against certificates before production.

2

Core Cutting

CNC step-lap core cutting for low-loss grain-oriented silicon steel. Core loss measured before assembly.

3

Winding

Controlled winding tension, turn-count verification, and insulation paper application for each coil.

4

Assembly

Core-coil assembly with dimensional checks for fit, clearance, and clamping force.

5

Vacuum Drying

High-vacuum drying ovens remove moisture from insulation before oil impregnation.

6

Oil Filling

Filtered insulating oil with breakdown voltage >70kV/2.5mm and moisture <10ppm.

7

Final Testing

Full routine test per IEC 60076-1 — insulation, resistance, ratio, losses, withstand.

8

Packing

Sea-worthy export packing with shock-fixed crating for ocean shipping.

9

Shipping

On-time delivery with documentation — test reports, drawings, manuals in English.