Renewable Energy

Solar Step-up Transformer

Multi-winding, harmonic-tolerant step-up transformer matched to PV inverters. Designed for solar power plant inverter-to-grid step-up applications.

100–3150 kVACapacity
IEC 60076Standard
Solar Step-up Transformer

Technical Parameters

Standard parameter ranges for this model. Special requirements can be assessed by our engineering team — contact us for custom specifications.

ParameterStandard Range
Rated capacity100–3150 kVA
Primary voltage (LV)0.4 / 0.69 / 0.8 kV (inverter output)
Secondary voltage (HV)10, 20, 35 kV (collection grid)
Frequency50 Hz or 60 Hz
Phase3-phase
Vector groupDyn11, Dyn5 (custom for multi-winding)
Impedance4.0% – 6.0% (K-factor adjusted)
Cooling methodONAN / ONAF
Tap changerOff-circuit (OCTC) ±2×2.5%
Insulation levelLI75AC35 / LI95AC50
Temperature rise65K (oil); 65K (winding)
No-load lossPer IEC 60076 (low-loss design)
Load lossPer IEC 60076 (K-factor adjusted)
Noise level≤55 dB
Protection levelIP54 (outdoor standard); IP65 available
Applicable standardsIEC 60076, IEEE 1547, IEEE C57.12.00
Ambient temperature-25°C to +50°C (derating above 40°C)
Altitude≤1000m (up to 4000m with derating)
AccessoriesTemp gauges, Buchholz, pressure relief, breather, IP54 enclosure
Special parameters (non-standard voltage, capacity, impedance, or environmental conditions) can be assessed by our engineers. Response within 12 hours, full proposal within 48 hours.

Product Advantages

Verifiable benefits — not empty claims. Here’s exactly what you get when you choose JINXING.

☀️

Inverter-Matched

Multi-winding design for 1–4 MPPT/inverter inputs — reduces transformer count.

〰️

Harmonic-Tolerant

K-factor rated (K-4 to K-20), eddy-current loss controlled for THDi up to 30%.

🌡️

Desert-Ready

IP54 outdoor, sand/dust resistant, UV-resistant enclosure.

🏔️

High Altitude

Designs available up to 4000m with derating.

🧪

Full Routine Test

IEC 60076-1 + harmonic loss verification.

📄

English Docs

Complete documentation including harmonic analysis.

Low-voltage terminals, cooling system and medium-voltage cable box on a solar transformer

Applications

Where this transformer is used — connecting the product to real-world industry applications.

☀️

Utility Solar

1–500 MW utility-scale PV plant inverter step-up.

🏠

Distributed Solar

Commercial rooftop and distributed PV systems.

🔋

Solar + Storage

Hybrid solar + battery storage step-up transformers.

Collection Grid

10/20/35kV collection grid for PV farms.

Quality Proof — 9-Step Manufacturing Process

Every transformer passes through 9 quality-controlled stages, from raw material to shipping. Full traceability with documentation at every step.

Solar transformer winding, enclosure assembly and high-voltage testing
1

Material Inspection

Raw material verification — core steel, copper, oil, accessories checked against certificates before production.

2

Core Cutting

CNC step-lap core cutting for low-loss grain-oriented silicon steel. Core loss measured before assembly.

3

Winding

Controlled winding tension, turn-count verification, and insulation paper application for each coil.

4

Assembly

Core-coil assembly with dimensional checks for fit, clearance, and clamping force.

5

Vacuum Drying

High-vacuum drying ovens remove moisture from insulation before oil impregnation.

6

Oil Filling

Filtered insulating oil with breakdown voltage >70kV/2.5mm and moisture <10ppm.

7

Final Testing

Full routine test per IEC 60076-1 — insulation, resistance, ratio, losses, withstand.

8

Packing

Sea-worthy export packing with shock-fixed crating for ocean shipping.

9

Shipping

On-time delivery with documentation — test reports, drawings, manuals in English.

Need a Custom Transformer Solution?

Our engineering team can assess non-standard voltage, capacity, impedance, or environmental conditions — and deliver a full proposal within 48 hours.

Leave a Reply

Your email address will not be published. Required fields are marked *

Scroll to Top