Solar Solution

Solar Power Plant Solution

Complete transformer solution for utility-scale and distributed solar PV plants — from inverter step-up to grid connection. Multi-winding, harmonic-tolerant, outdoor-ready designs for 1–500 MW installations.

Application

System Architecture: Inverter to Grid

PV panels → String/Central inverter → Step-up transformer → Collection grid → Main step-up transformer → Grid connection. JINXING provides transformers at every stage.

Stage 1

Inverter Step-up (0.4–0.8kV → 10–35kV)

Multi-winding transformers matched to central or string inverters. 1–4 MPPT inputs, harmonic-tolerant winding design.

Stage 2

Collection Grid (10–35kV)

Pad-mount or compact substations collecting power from multiple inverter transformers. Switchgear + protection integrated.

Stage 3

Main Step-up (35kV → 110/220kV)

Main power transformer stepping up to grid voltage. OLTC, full type test, witnessed FAT.

Application

Customer Purchase Options

Option 1

Transformer Only

You have switchgear and enclosure. We supply the transformer to your spec.

Option 2

Transformer + Switchgear

Transformer matched with HV/LV switchgear, protection and monitoring.

Option 3

Pre-fabricated Box Substation

Complete substation: transformer + switchgear + enclosure, ready to install on site.

Option 4

Design & Selection Support

Our engineers help you select the right transformer, winding config, and capacity for your plant.

Engineering Data

Key Technical Parameters

Voltage range0.4/0.69/0.8kV → 10/20/35kV (step-up); 35kV → 110/220kV (main)
Capacity100–3150 kVA (inverter); 6.3–200 MVA (main step-up)
Multi-winding1–4 winding for multiple MPPT/inverter inputs, reduce transformer count
Box substation100–2500 kVA, transformer + HV/LV switchgear + enclosure, ready to install
Ambient temperature-25 to +50°C (derating above 40°C, +5°C per 100m altitude)
Altitude≤1000m standard, up to 4000m with derating
ProtectionIP54/IP55 outdoor (dust, rain); IP65 optional; salt-spray resistant coating
EnvironmentalSand/dust resistant, UV-resistant enclosure, anti-corrosion treatment
Grid codeIEC 60076, IEEE 1547, local utility requirements (e.g., GB/T 19964)
LossesLow-loss design; amorphous core option for no-load loss reduction
HarmonicsK-factor rated (K-4 to K-20), eddy-current loss controlled for THDi up to 30%